Mixed Flow Fans

HLF-6 Mixed Flow Fan Cabinet

Mixed-flow fan cabinet for air supply and exhaust in civil, commercial and industrial construction projects.

  • Fan diameter Ø570–Ø2,050 mm
  • Cabinet-type mixed-flow configuration
  • Fan Diameter: φ570~φ2050mm
  • Air volume: 444~134892m³/h
  • Wind pressure: 44~1905Pa
Airflow444–134,892 m³/h
Pressure44–1,905 Pa
Chat on WhatsApp →
Product Details

Product Overview

The HLF-6 mixed-flow fan cabinet provides air supply and exhaust for civil, commercial and industrial construction projects. Its cabinet design supports airflow requirements up to 134,892 m³/h.

HLF-6 Mixed Flow Fan Cabinet belongs to Yosinda’s mixed flow fans range. Typical uses include Air supply and exhaust in civil, commercial and industrial construction projects. Mixed-flow selection brings airflow and duct pressure into the same review. Building and industrial supply or exhaust installations should account for bends, filters and terminal losses. Available space and maintenance access help determine the final fan size and arrangement.

Published configuration information includes Fan Diameter: φ570~φ2050mm; Air volume: 444~134892m³/h; Wind pressure: 44~1905Pa. Range figures cover different sizes and operating points; they should not be read as simultaneous performance for one unit. Confirm the selected fan’s performance and dimensions with our engineering team.

Manufacturing takes place in Wuhu, Anhui, China. Send the duty point, local voltage and frequency, drawings and destination with your inquiry. Yosinda can review the mechanical configuration, motor options and export packing for the order. The quotation confirms the delivery scope and applicable inspection requirements before production.

Key Features

  • Fan diameter Ø570–Ø2,050 mm
  • Cabinet-type mixed-flow configuration
  • Fan Diameter: φ570~φ2050mm
  • Air volume: 444~134892m³/h
  • Wind pressure: 44~1905Pa
Product Data

Technical Specifications

Published ranges support initial selection. Final performance and configuration are confirmed for your operating point.

HLF-6 Mixed Flow Fan Cabinet specifications
ModelHLF-6
Airflow444–134,892 m³/h
Pressure44–1,905 Pa
Additional Specifications
HLF-6 Mixed Flow Fan Cabinet additional specifications
Product NameHLF-6 Mixed Flow Fan Cabinet
ApplicationWidely used for air supply and exhaust in civil, commercial and industrial construction projects
Fan Diameterφ570–φ2050mm
Catalog NotePer the latest GB48144—2026 General Technical Requirements for Fire Fans, fan model numbers above may change. Confirm full requirements with sales prior to purchase.
Suitable Industries

Applications

Air supply and exhaust in civil, commercial and industrial construction projects.

Customization Options

Available options depend on the model and duty. Confirm the required configuration with our team.

Airflow
Confirmed with the selected model and project requirements.
Static Pressure
Confirmed with the selected model and project requirements.
Motor Power
Confirmed with the selected model and project requirements.
Voltage
Confirmed with the selected model and project requirements.
Frequency
Confirmed with the selected model and project requirements.
Motor Brand
Confirmed with the selected model and project requirements.
Material
Confirmed with the selected model and project requirements.
Outlet Direction
Confirmed with the selected model and project requirements.
Structure
Confirmed with the selected model and project requirements.
Color
Confirmed with the selected model and project requirements.
Mounting
Confirmed with the selected model and project requirements.
OEM Branding
Confirmed with the selected model and project requirements.

Need a custom fan configuration?

Request a Quote

Manufacturing & Quality

Yosinda combines fan engineering with manufacturing in Wuhu, China. Production includes fabrication, welding, impeller balancing and assembly, followed by performance testing and final inspection. The applicable inspection scope and product certification are confirmed for each order.

  1. 01Raw Material
  2. 02Cutting & Fabrication
  3. 03Welding
  4. 04Impeller Balancing
  5. 05Assembly
  6. 06Performance Testing
  7. 07Final Inspection
  8. 08Packaging
FAQ

Frequently Asked Questions

How do I select the right HLF-6 configuration?

Send the airflow, pressure, gas temperature, handled medium, installation space and power supply. Our team will review the duty point and confirm a suitable configuration.

Can the airflow and pressure be customized?

Configuration options depend on the selected model. Share your target duty point so our engineers can confirm the available range.

Can you supply different voltage, frequency or motor brands?

Motor and electrical options are reviewed at quotation stage against the actual site power supply and selected fan.

Do you support OEM and custom mounting arrangements?

OEM branding, outlet direction and mounting requirements can be discussed with our team. Available options are confirmed before production.

Same Product Family

Related Products

View Products →
Request a Quote

Tell us about your operating conditions

Share the airflow, pressure, temperature, power supply and installation requirements. Our team will review the duty point with you.